To determine intra- and inter-day reliability of spine rasterstereographic system Formetric 4D with and without reflective markers. 26 healthy volunteers (M group) had two markers placed in correspondence of vertebra prominens and intergluteal cleft, and 24 volunteers (NM group) were assessed without markers. All participants were analyzed two times in the same day and one time on a separate day. Trunk length, kyphotic angle, lordotic angle, pelvic inclination, kyphotic and lordotic apex, right and left lateral deviation, Flèche cervicale and lombaire, trunk imbalance, pelvic tilt, inflection point, rotation correction, right and left surface rotation, pelvic torsion, trunk torsion were measured. Intraclass correlation coefficient (ICC) and Cronbach Alpha (Cα) were calculated. In M group, for intra-, inter-day, and overall evaluations the higher reliability coefficients were 0.971, 0.963, 0.958 (ICC) and 0.987, 0.983, 0.985 (Cα) for trunk length, kyphotic angle and lordotic apex respectively; while in NM group were 0.978, 0.982, 0.972 and 0.989, 0.991, 0.991 for trunk length. In M group the lower values were 0. 598, 0.515, 0.534 (ICC) and 0.742, 0.682, 0.784 (Cα) for trunk and pelvic torsion, in NM group 0.561, 0.537, 0.461 and 0.731, 0.695, 0.729 for left lateral deviation. The reliability of most parameters was excellent.

Intra- and Inter- day Reliability of Spine Rasterstereography

Baldari C
2013-01-01

Abstract

To determine intra- and inter-day reliability of spine rasterstereographic system Formetric 4D with and without reflective markers. 26 healthy volunteers (M group) had two markers placed in correspondence of vertebra prominens and intergluteal cleft, and 24 volunteers (NM group) were assessed without markers. All participants were analyzed two times in the same day and one time on a separate day. Trunk length, kyphotic angle, lordotic angle, pelvic inclination, kyphotic and lordotic apex, right and left lateral deviation, Flèche cervicale and lombaire, trunk imbalance, pelvic tilt, inflection point, rotation correction, right and left surface rotation, pelvic torsion, trunk torsion were measured. Intraclass correlation coefficient (ICC) and Cronbach Alpha (Cα) were calculated. In M group, for intra-, inter-day, and overall evaluations the higher reliability coefficients were 0.971, 0.963, 0.958 (ICC) and 0.987, 0.983, 0.985 (Cα) for trunk length, kyphotic angle and lordotic apex respectively; while in NM group were 0.978, 0.982, 0.972 and 0.989, 0.991, 0.991 for trunk length. In M group the lower values were 0. 598, 0.515, 0.534 (ICC) and 0.742, 0.682, 0.784 (Cα) for trunk and pelvic torsion, in NM group 0.561, 0.537, 0.461 and 0.731, 0.695, 0.729 for left lateral deviation. The reliability of most parameters was excellent.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11389/25942
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 60
  • ???jsp.display-item.citation.isi??? 58
social impact