Wearable devices with electrocardiographic (ECG) sensors offer a strong and practical alternative to clinical systems monitoring physiological parameters. Identifying key ECG waveform points is essential for extracting cardiac features (e.g., PR intervals, QRS duration, QT intervals) and understanding cardiac function. This study evaluates heart rate (HR) estimation accuracy and precision using the Zephyr BioHarness 3.0 (reference device) and a 12-lead wireless ECG (test device) during rest and treadmill walking. It also develops an algorithm to detect PQRST wave points for extracting ECG features during various conditions (rest, walking, inclined walking, recovery). Compared to the BioHarness, the test device demonstrated high agreement in HR estimation (mean ± standard deviation = 0.11 bpm ± 2.04 bpm, p = 0.99), with minimal error in resting conditions. However, motion artifacts introduced variability, particularly during walking and inclined walking (walking MAE: 1.47 bpm ± 2.07 bpm; inclined walking MAE: 2.09 bpm ± 5.78 bpm; mean ± standard). Feature extraction analysis revealed increased errors in QRS and QT interval detection under dynamic conditions. In contrast, P-wave and PR interval related residuals were lower under dynamic conditions (inclined walking P-wave MAE: 18.22 ms ± 14.16 ms; PR interval MAE: 28.58 ms ± 22.66 ms; mean ± standard).

Metrological Evaluation of Wearable ECG Systems: Heart Rate Estimation and PQRST Waveform Analysis

Cosoli, Gloria;Scalise, Lorenzo
2025-01-01

Abstract

Wearable devices with electrocardiographic (ECG) sensors offer a strong and practical alternative to clinical systems monitoring physiological parameters. Identifying key ECG waveform points is essential for extracting cardiac features (e.g., PR intervals, QRS duration, QT intervals) and understanding cardiac function. This study evaluates heart rate (HR) estimation accuracy and precision using the Zephyr BioHarness 3.0 (reference device) and a 12-lead wireless ECG (test device) during rest and treadmill walking. It also develops an algorithm to detect PQRST wave points for extracting ECG features during various conditions (rest, walking, inclined walking, recovery). Compared to the BioHarness, the test device demonstrated high agreement in HR estimation (mean ± standard deviation = 0.11 bpm ± 2.04 bpm, p = 0.99), with minimal error in resting conditions. However, motion artifacts introduced variability, particularly during walking and inclined walking (walking MAE: 1.47 bpm ± 2.07 bpm; inclined walking MAE: 2.09 bpm ± 5.78 bpm; mean ± standard). Feature extraction analysis revealed increased errors in QRS and QT interval detection under dynamic conditions. In contrast, P-wave and PR interval related residuals were lower under dynamic conditions (inclined walking P-wave MAE: 18.22 ms ± 14.16 ms; PR interval MAE: 28.58 ms ± 22.66 ms; mean ± standard).
2025
Inglese
Panni, L., Cosoli, G., Scalise, L.
2025 IEEE Medical Measurements & Applications (MeMeA)
contributo
ELETTRONICO
20th IEEE International Symposium on Medical Measurements and Applications, MeMeA 2025
2025
1
6
6
979-8-3315-2347-3
https://ieeexplore.ieee.org/document/11068076
Institute of Electrical and Electronics Engineers Inc.
Esperti anonimi
2025
Chania
Internazionale
biomedical signal processing; ECG feature extraction; electrocardiogram; heart rate; metrological characterization; wearable device
no
none
Panni, Luna; Cosoli, Gloria; Scalise, Lorenzo
273
info:eu-repo/semantics/conferenceObject
3
4 Contributo in Atti di Convegno (Proceeding)::4.1 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11389/75476
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact