To demonstrate the utility of 12-lead Holter monitoring underwater. METHODS: A Holter monitor, recording a 12-lead electrocardiogram (ECG) underwater, was applied to 16 pre-trained volunteer scuba divers (13 males and three females). Dive computers were synchronized with the Holter recorder to correlate the ECG tracings with diving events. Our main objective was to demonstrate the utility of recording over a period of time a good quality 12-lead ECG underwater. The ECGs were analyzed for heart rate (HR), arrhythmias, conduction abnormalities and ischaemic events in relation to various stages of diving as follows: baseline, pre diving, diving, and post diving. RESULTS: The ECG tracings were of good quality with minimal artefacts. Analysis of variance (ANOVA) demonstrated a significant difference in HR during the various diving stages (P < 0.0001). Other recorded ECG abnormalities included supraventricular ectopic beats (four cases), ventricular ectopic beats (eight cases) and ventricular couplets (two cases). Conduction abnormalities included rate-dependent right and left bundle branch block; however, these findings were previously known in these divers. No evidence of ischaemia was seen. CONCLUSION: Continuous 12-lead Holter monitoring underwater can produce good quality tracings. Further studies are necessary to assess its usefulness in divers at risk for or with known coronary artery disease, and its comparison with other forms of cardiac stress tests.
12-lead Holter monitoring in diving and water sports: a preliminary investigation
PADULO, JOHNNY;
2014-01-01
Abstract
To demonstrate the utility of 12-lead Holter monitoring underwater. METHODS: A Holter monitor, recording a 12-lead electrocardiogram (ECG) underwater, was applied to 16 pre-trained volunteer scuba divers (13 males and three females). Dive computers were synchronized with the Holter recorder to correlate the ECG tracings with diving events. Our main objective was to demonstrate the utility of recording over a period of time a good quality 12-lead ECG underwater. The ECGs were analyzed for heart rate (HR), arrhythmias, conduction abnormalities and ischaemic events in relation to various stages of diving as follows: baseline, pre diving, diving, and post diving. RESULTS: The ECG tracings were of good quality with minimal artefacts. Analysis of variance (ANOVA) demonstrated a significant difference in HR during the various diving stages (P < 0.0001). Other recorded ECG abnormalities included supraventricular ectopic beats (four cases), ventricular ectopic beats (eight cases) and ventricular couplets (two cases). Conduction abnormalities included rate-dependent right and left bundle branch block; however, these findings were previously known in these divers. No evidence of ischaemia was seen. CONCLUSION: Continuous 12-lead Holter monitoring underwater can produce good quality tracings. Further studies are necessary to assess its usefulness in divers at risk for or with known coronary artery disease, and its comparison with other forms of cardiac stress tests.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.