Starting from the Rome Hydrogen Refuelling Station demand of 65 kg/day, techno-economics of production systems and balance of plant for small scale stations have been analysed. A sensitivity analysis has been done on Levelised Cost of Hydrogen (LCOH) in the range of 0 to 400 kg/day, varying capacity factor and availability hours or travel distance for alkaline electrolysers, biomass gasification and hydrogen delivery. As expected, minimum LCOH for electrolyser and gasifier is found at 400 kg/day and 24 h/day, equal to 12.71 €/kg and 5.99 €/kg however, for operating hours over 12 and 10 h/day the differential cost reaches a plateau (below 5%), for electrolyser and gasifier respectively. For the Rome station design, 160 kWe of electrolysers 24 h/day and 100 kWth gasifier at 8 h/day, LCOH (11.85 €/kg) was calculated considering the modification of the cost structure due to the existing equipment, which is convenient respect the use of a single technology, except for 24 h/day gasification.

Techno-economic analysis of in-situ production by electrolysis, biomass gasification and delivery systems for Hydrogen Refuelling Stations: Rome case study

Del Zotto L.;
2018-01-01

Abstract

Starting from the Rome Hydrogen Refuelling Station demand of 65 kg/day, techno-economics of production systems and balance of plant for small scale stations have been analysed. A sensitivity analysis has been done on Levelised Cost of Hydrogen (LCOH) in the range of 0 to 400 kg/day, varying capacity factor and availability hours or travel distance for alkaline electrolysers, biomass gasification and hydrogen delivery. As expected, minimum LCOH for electrolyser and gasifier is found at 400 kg/day and 24 h/day, equal to 12.71 €/kg and 5.99 €/kg however, for operating hours over 12 and 10 h/day the differential cost reaches a plateau (below 5%), for electrolyser and gasifier respectively. For the Rome station design, 160 kWe of electrolysers 24 h/day and 100 kWth gasifier at 8 h/day, LCOH (11.85 €/kg) was calculated considering the modification of the cost structure due to the existing equipment, which is convenient respect the use of a single technology, except for 24 h/day gasification.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11389/30473
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 32
  • ???jsp.display-item.citation.isi??? ND
social impact