Repairing critical human skull injuries requires the production and use of customized cranial implants and involves the integration of computer aided design and manufacturing (CAD and CAM). The main causes for large cranial defects are trauma, cranial tumors, infected craniotomy bone flaps and external neurosurgical decompression. The success of reconstructive cranial surgery depends upon: the preoperative evaluation of the defect, the design and manufacturing of the implant, and the skill of the operating surgeon. Cranial implant design is usually carried out manually using CAD although this process is very time-consuming and the quality of the end product depends wholly upon the skill of the operator. This paper presents an alternative automated method for the design of custom-made cranial plates in a PHANToM ®-based haptic environment, and their direct fabrication in biocompatible metal using electron beam melting (EBM) technology.

Direct fabrication through electron beam melting technology of custom cranial implants designed in a phantom based haptic

RAFFAELI, ROBERTO
2008-01-01

Abstract

Repairing critical human skull injuries requires the production and use of customized cranial implants and involves the integration of computer aided design and manufacturing (CAD and CAM). The main causes for large cranial defects are trauma, cranial tumors, infected craniotomy bone flaps and external neurosurgical decompression. The success of reconstructive cranial surgery depends upon: the preoperative evaluation of the defect, the design and manufacturing of the implant, and the skill of the operating surgeon. Cranial implant design is usually carried out manually using CAD although this process is very time-consuming and the quality of the end product depends wholly upon the skill of the operator. This paper presents an alternative automated method for the design of custom-made cranial plates in a PHANToM ®-based haptic environment, and their direct fabrication in biocompatible metal using electron beam melting (EBM) technology.
2008
Inglese
STAMPA
30
8
3186
3192
7
http://www.sciencedirect.com/science/article/pii/S0261306908005554
http://www.scopus.com/inward/record.url?eid=2-s2.0-67349210322&partnerID=40&md5=88f613bbc0a2be90829ad54761a3741d
Esperti anonimi
Custom cranial implant; Electron beam melting (EBM); Haptic environment; PHANToM-based tools
Received 15 September 2008; accepted 15 November 2008. Available online 27 November 2008.
no
3
info:eu-repo/semantics/article
262
Mazzoli, A; Germani, M; Raffaeli, Roberto
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11389/479
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 81
  • ???jsp.display-item.citation.isi??? 67
social impact