Fabric Reinforced Cementitious Matrix (FRCM) systems are promising solutions for the confinement of masonry columns because they demonstrate strengthening effectiveness and, at the same time, compatibility with historical substrates. Nevertheless, the matrix is responsible for the stress-transfer from the structural element to the fabric-reinforcement. Therefore, in the case of poor-quality mortar, the effectiveness of the strengthening can be limited or even compromised. On the other hand, the low content of fibers utilized for FRCM systems generally involves the need to apply more layers in order to accomplish design requirements and a continuous configuration of the reinforcement is more often addressed. Few experimental and theoretical investigations have been targeted to the before mentioned aspects in the recent past, namely the influence of the kind of mortar, the number of layers, and the strengthening configuration (continuous, discontinuous) on the effectiveness of confinement. The present paper refers to the results of an experimental investigation on FRCM confined clay brick masonry. A series of small-scale masonry columns were tested under monotonic centered load until collapse. The varied parameters were the number of confining layers (i.e., 1, 2, and 3) and the confinement configuration (i.e., continuous and discontinuous). The performed research aims to contribute in strengthening to the knowledge in the field of FRCM-confinement, mainly focusing on some of the mentioned unexplored aspects (number of layers, strengthening configuration) that could be considered for validation/improvement of analytical design-oriented formulas. In particular, some analytical models, available in the technical literature, were adopted for predicting the herein reported experimental results. Even if based on few experimental results, the outcomes showed that the number of FRCM-layers and the confinement configuration were crucial parameters affecting the confining effectiveness. The compressive strength was satisfactorily predicted in all cases by the two available utilized models. On the other hand, an improvement in the utilized AOM model is suggested in order to include the stress–strain curves of the hardening type.
Confinement of masonry columns with the FRCM-system: Theoretical and experimental investigation
Verre S.Membro del Collaboration Group
2020-01-01
Abstract
Fabric Reinforced Cementitious Matrix (FRCM) systems are promising solutions for the confinement of masonry columns because they demonstrate strengthening effectiveness and, at the same time, compatibility with historical substrates. Nevertheless, the matrix is responsible for the stress-transfer from the structural element to the fabric-reinforcement. Therefore, in the case of poor-quality mortar, the effectiveness of the strengthening can be limited or even compromised. On the other hand, the low content of fibers utilized for FRCM systems generally involves the need to apply more layers in order to accomplish design requirements and a continuous configuration of the reinforcement is more often addressed. Few experimental and theoretical investigations have been targeted to the before mentioned aspects in the recent past, namely the influence of the kind of mortar, the number of layers, and the strengthening configuration (continuous, discontinuous) on the effectiveness of confinement. The present paper refers to the results of an experimental investigation on FRCM confined clay brick masonry. A series of small-scale masonry columns were tested under monotonic centered load until collapse. The varied parameters were the number of confining layers (i.e., 1, 2, and 3) and the confinement configuration (i.e., continuous and discontinuous). The performed research aims to contribute in strengthening to the knowledge in the field of FRCM-confinement, mainly focusing on some of the mentioned unexplored aspects (number of layers, strengthening configuration) that could be considered for validation/improvement of analytical design-oriented formulas. In particular, some analytical models, available in the technical literature, were adopted for predicting the herein reported experimental results. Even if based on few experimental results, the outcomes showed that the number of FRCM-layers and the confinement configuration were crucial parameters affecting the confining effectiveness. The compressive strength was satisfactorily predicted in all cases by the two available utilized models. On the other hand, an improvement in the utilized AOM model is suggested in order to include the stress–strain curves of the hardening type.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.