Healthcare is expected to increasingly shift care out of inpatient settings thanks to wearable monitoring systems. Photoplethysmography (PPG) is an optical technique already integrated into wrist-worn commercial products which presents significant advantages in terms of cost and dimensions. PPG-based devices, despite their ability to detect multiple cardiovascular parameters, are affected by several influencing conditions that depend both on technological or environmental variables, and on intra- and inter-subject variability that influences the whole measurement chain and reliability, hindering an objective characterization of PPG devices. Plus, the lack of standardization for data collection and processing leads to the lack of generalizability and reproducibility of results, preventing the full exploitation of the potential prognostic capacity of this technology. Thus, this review aims not only to summarize the main influencing parameters of PPG technology, which should be addressed when testing the sensor, but also to suggest tentative guidelines for a possible future standardization initiative.

Photoplethysmograhic sensors, potential and limitations: Is it time for regulation? A comprehensive review

Cosoli G.;Scalise L.;
2023-01-01

Abstract

Healthcare is expected to increasingly shift care out of inpatient settings thanks to wearable monitoring systems. Photoplethysmography (PPG) is an optical technique already integrated into wrist-worn commercial products which presents significant advantages in terms of cost and dimensions. PPG-based devices, despite their ability to detect multiple cardiovascular parameters, are affected by several influencing conditions that depend both on technological or environmental variables, and on intra- and inter-subject variability that influences the whole measurement chain and reliability, hindering an objective characterization of PPG devices. Plus, the lack of standardization for data collection and processing leads to the lack of generalizability and reproducibility of results, preventing the full exploitation of the potential prognostic capacity of this technology. Thus, this review aims not only to summarize the main influencing parameters of PPG technology, which should be addressed when testing the sensor, but also to suggest tentative guidelines for a possible future standardization initiative.
2023
Inglese
ELETTRONICO
218
20
https://www.sciencedirect.com/science/article/pii/S0263224123007145
Esperti anonimi
Heart Rate (HR); Motion artifacts; Optical sensors; Photoplethysmography (PPG); Sources of inaccuracy; Standardization
no
10
info:eu-repo/semantics/article
262
Scardulla, F.; Cosoli, G.; Spinsante, S.; Poli, A.; Iadarola, G.; Pernice, R.; Busacca, A.; Pasta, S.; Scalise, L.; D'Acquisto, L.
1 Contributo su Rivista::1.1 Articolo in rivista
none
   Sensoristica intelligente, infrastrutture e modelli gestionali per la sicurezza di soggetti fragili
   4FRAILTY
   Italian Ministry of Education, University and Research
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11389/58551
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 97
  • ???jsp.display-item.citation.isi??? 84
social impact