Background: Copper dyshomeostasis has been implicated in a subset of Alzheimer's disease (AD) patients, characterized by elevated non-ceruloplasmin-bound copper (non-Cp Cu). However, traditional methods for estimating non-Cp Cu are indirect and analytically imprecise. This study introduces and validates a direct assay for exchangeable copper (ExcCu) by inductively coupled plasma-mass spectrometry (ICP-MS), compliant with Clinical and Laboratory Standards Institute (CLSI) guidelines. Methods: We performed analytical validation of the ExcCu assay following CLSI protocols (EP5, EP6, EP7, EP9, EP15, and EP28). ExcCu and other copper-related biomarkers were quantified in serum samples from 154 healthy controls, 82 AD patients, and 10 patients with Wilson disease (WD). Diagnostic performance was evaluated via receiver operating characteristic (ROC) curve analysis, and inter-method agreement was assessed using Bland-Altman plots. Results: The ExcCu assay demonstrated excellent linearity, precision (CV < 6%), and inter-laboratory reproducibility. Among AD patients, ExcCu levels were significantly elevated compared to controls (p < 0.001). ExcCu distinguished AD from controls with an AUC of 0.80 and a specificity of 95%. Compared to non-Cp Cu, ExcCu yielded no negative values and showed reduced bias. The relative exchangeable copper (REC) index was more effective in differentiating AD from WD (AUC = 0.88). Conclusions: The validated ExcCu assay overcomes the limitations of the traditional non-Cp Cu calculation, offering a reliable biomarker for copper-related AD subtypes. Its high specificity supports its use in patient stratification, potentially contributing to personalized approaches in AD diagnosis and therapy.

CLSI Validation of Exchangeable Copper Determination in Serum by ICP-MS: A Focus on Alzheimer's Disease and Wilson Disease

Squitti, Rosanna
;
2025-01-01

Abstract

Background: Copper dyshomeostasis has been implicated in a subset of Alzheimer's disease (AD) patients, characterized by elevated non-ceruloplasmin-bound copper (non-Cp Cu). However, traditional methods for estimating non-Cp Cu are indirect and analytically imprecise. This study introduces and validates a direct assay for exchangeable copper (ExcCu) by inductively coupled plasma-mass spectrometry (ICP-MS), compliant with Clinical and Laboratory Standards Institute (CLSI) guidelines. Methods: We performed analytical validation of the ExcCu assay following CLSI protocols (EP5, EP6, EP7, EP9, EP15, and EP28). ExcCu and other copper-related biomarkers were quantified in serum samples from 154 healthy controls, 82 AD patients, and 10 patients with Wilson disease (WD). Diagnostic performance was evaluated via receiver operating characteristic (ROC) curve analysis, and inter-method agreement was assessed using Bland-Altman plots. Results: The ExcCu assay demonstrated excellent linearity, precision (CV < 6%), and inter-laboratory reproducibility. Among AD patients, ExcCu levels were significantly elevated compared to controls (p < 0.001). ExcCu distinguished AD from controls with an AUC of 0.80 and a specificity of 95%. Compared to non-Cp Cu, ExcCu yielded no negative values and showed reduced bias. The relative exchangeable copper (REC) index was more effective in differentiating AD from WD (AUC = 0.88). Conclusions: The validated ExcCu assay overcomes the limitations of the traditional non-Cp Cu calculation, offering a reliable biomarker for copper-related AD subtypes. Its high specificity supports its use in patient stratification, potentially contributing to personalized approaches in AD diagnosis and therapy.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11389/73816
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact